LPG bulk tanks are normally filled to 87% of their
capacity to allow sufficient vapour space above the
liquid level for the propane to expand and contract
with changes in temperature.
Calor's aim is to provide at least 6 weeks gas storage
at maximum gas consumption rate to ensure
security and continuity of supply. This may be increased
where access may be difficult during the
winter months.
Full central heating and hot water for an average
property represents an annual gas consumption of
3000 to 5000 litres per year.
It should be noted that LPG bulk tanks can be grouped
to provide the required storage capacity and off-take
rate.
|