» Refuelling instructions for Calor 29 litre refillable cylinders and fixed fuel tanks
For full information on refuelling instructions for Calor 29 litre refillable cylinders and fixed fuel tanks please refer to the pdf 'Operating instructions for 29 litre refillable forklift truck cylinders'.
» Refuelling Instructions for refillable cylinders
For full information on refuelling instructions please refer to the pdf 'Refillable forklift truck cylinders'.
» Action in the event of an emergency relating to refillable cylinders
In the even to a substantial spillage of LPG or fire the following steps should be taken:
- Shut OFF tank valves D & K and filler valve J fuel dispenser isolating valves if safe to do so and isolate the electrical master switch.
- Summon the Fire Brigade and advise the presence of LPG
- Remove or extinguish any source of ignition
- Do not attempt to start engines of vehicles, which may be in the vicinity
- CONTACT CALOR GAS EMERGENCY SERVICE 0845 7 444 999
- Keeep personnel and members of public away from the general area in which vapour may be spreading
- Alert neighbours if appropriate and advise of possible dangers, especially if there are cellers, basements or depressions in which vapour could collect.
For minor gas leaks or hose breakaway:
- Immediately report to your supervisor or manager, so they can contact the CALOR GAS EMERGENCY SERVICE 0845 7 444 999
» Safety Instructions for filling Calor 29 litre refillable cylinders & fixed fuel tanks
Operators must be trained to fill liquid off-take, Calor refillable 29 litre cylinders and fixed fuel tanks (FFT). Ensure that suitable Personal Protective Equipment is used when the refuelling operation is taking place. Neoprene gloves, preferably gaunlets, goggles or face shield, long sleeved cotton overalls and safety footwear are recommended.
Please note: Where non-Calor refillable cylinders are being used, please refer to the manufacturers instructions for additional guidance.
» Safety Instructions for refillable cylinders
Operators must be trained to fill liquid off-take, Calor refillable cylinders. Ensure that suitable Personal Protection Equipment is used when the refuelling operation is taking place. Gloves preferably gauntlets, goggles or face shield, long sleeved cotton overalls and safety footwear are recommended.
Please note: Where non-Calor refillable cylinders are being used, please refer to the manufacturers instructions for additional guidance.
» Note:
This procedure may be supplemented by your Company's Health and Safety procedures related to the Health and Safety at Work Act 1974. Be aware of them and follow the action indicated when an unsafe situation occurs.